Well-water treatment planner
Turn your lab results into a sensible treatment order, with a reason and a source for each stage.
Planning estimates only. Verify your numbers with a certified lab test, and have any installation done by a licensed plumber. Results are estimates, not engineering, plumbing, medical, or legal advice, and no health claims are made. See the terms.
Understand the chain
Why this order
- pH neutralizer (if pH is below 7.0).Protects pipes and prepares the water for iron removal.
- Oxidation and filtration.Air injection or chemical feed turns dissolved iron, manganese and sulfur into particles a backwashing filter can catch.
- Carbon (when needed).Removes leftover oxidant and polishes odor.
- Sediment polish (optional).Catches fine particles before the softener.
- Softener.Handles hardness once iron is gone.
Numbers the planner uses
| Measure | Threshold | Action |
|---|---|---|
| pH | below 7.0 | Neutralizer first (EPA secondary range is 6.5 to 8.5) |
| Iron | above 0.3 ppm | Oxidizing filter, or iron-rated softener if 2 ppm or less and no sulfur or manganese |
| Iron | above 10 ppm (iron + 2 x manganese) | Chemical oxidation and backwashing filter |
| Manganese | above 0.05 ppm | Catalytic media; air alone may not be enough |
| Sulfur smell | slight / strong | Air injection / chemical oxidation plus carbon |
| Hardness | 3.5 gpg or more | Softener last (1 to 3.5 gpg optional) |
Source: EPA: Secondary Drinking Water Standards (iron, manganese, pH, odor)
Frequently asked questions
Why does pH come first?
Low-pH water can corrode plumbing and keeps many iron-removal media from working as designed. Neutralizing first protects every later stage.
Why is the softener last?
Softener resin is sensitive to iron and sediment. Removing them upstream protects the resin and lets you size the softener on hardness alone.
Do I need a lab test if I already smell sulfur?
Yes. Smell tells you something is there, not how much, and the right treatment depends on the numbers. A certified lab test is the starting point.
What is the iron equivalent?
Manganese is harder to remove than iron, so the planner counts iron plus 2 times manganese when judging whether air injection is enough.